Data sheet DIN EN 13956
Date of issue: April 17th 2008
VEDAFOL® F 12
0958

Manufacturer VEDAG GmbH Factories:
Flinschstr. 10-16 Geisfelder Stra.e 85-91, D-96050 Bamberg
D-60388 Frankfurt Huttenheimer Stra.e 31, D-76661 Philippsburg-Rheinsheim
Zaluzi 1, CZ-43670 Litvinov

VEDAG GmbH has been certified to EN ISO 9001 since 1995. The certificates for the  manufacturing inspection to DIN EN 13707 and DIN EN 13969 were established in October 2005 and February 2006:

Certificate of VEDAG GmbH:

• by EN ISO 9001 since 1995 Certificate of Factory Production Control
• Bituminous membranes by DIN EN 13707 and DIN EN 13969 (0958-CPD-DK001/1, DK002/1, DK003/1, DK004/1, DK006/1, DK007/1)
• Synthetic membranes by DIN EN 13956 (FPO: 1349 -CPD -038, POCB: 0958 -CPD -DK036/1, PVC: 0958 -CPD-DK034).
Description of the
VEDAFOL® F 12 is a multilayered synthetic roofing membrane based on PVC-P with
product
reinforcement inside for single-ply roof insulations in highest quality by DIN EN 13956 and
DIN V 20000-201 with technical values higher than the standards. Topside UV-stabilized, smooth, standard colour grey (other colours on request)
Coatings PVC-P, not bitumen-compatible
Carrier Diagonal reinforced Polyester fabric > 80 g/m., non wick coated
Bottom side smooth

Product benefits:
• High mechanical and thermal resistance E1 by DIN 18531-2 and DIN V 20000-201
• Dimensional stable
• Highly resistant to tearing, tear propagation and nail shank
• High ageing resistance, well proven since 40years.
• Rational application because of 20 m roll length and up till 2,12 width
• Fulfils the regulation of the european standards and fire protection regulations, classification Broof (t1) „hard roof“ on EPS (with 120 g/m. raw glass fleeze as separation layer) and on mineral wool.
Field of application
VEDAFOL® F 12 is used as single-ply mechanically fixed roof insulation.

Method of application
VEDAFOL® F 12 will be applied with mechanical fixings according to the wind load calculation with step on resistant fasteners on the edge of the seam. Longitudinal and cross seams will be welded min. 2 cm wide with hot air or min. 3 cm wide with THF solvent welding and must be pressed on with the pressure roll. T-joints must be cut in an 45°angle. To avoid capillary the bottom membrane edge must be chamfered (with hot air or edge plane).
Storage
VEDAFOL® F 12 must be stored protected from moisture and heat. During the cold seasons the rolls must be brought to the site from a frost protected storage place directly before use.
Disposal
VEDAFOL® -synthetic membranes and other site waste (European Waste Catalogue EWC-No. 17 02 03 “plastics”) can be thermally recycled without any harm for the environment.

Additional Advice
The regulations of the Employer’s Liability Insurance Association must be adhered.